Expert Rev Cardiovasc Ther. 2026 Nov 15. doi: 10.1080/14779072.2026.2763891. Online ahead of print.
ABSTRACT
BACKGROUND: Intracardiac echocardiography (ICE) is increasingly being used to guide left atrial appendage closure (LAAC).
RESEARCH DESIGN AND METHODS: This is an evaluation of a single operator's outcomes treating all-comers patient population referred for LAAC between September 2022 and September 2024. The operator transitioned from TEE to AcuNav Volume 4D-ICE guidance in August 2023. The primary objective was successful device implantation. Secondary objectives were rate of complications, and cessation of anticoagulation at 45 days.
RESULTS: 81 patients had LAAC with 4D-ICE guidance compared to 35 patients with TEE. Baseline characteristics were similar. Device implant was successful in 94% with ICE and 100% with TEE. There was 1 non-disabling stroke in the ICE group and 2 mortality events in the TEE group within 30 days of the procedure. Rates of anticoagulation cessation at 45 days were 91% with ICE and 89% with TEE.
CONCLUSIONS: 4D-ICE can be used to guide LAAC with the Watchman FLX with excellent procedural success and minimal periprocedural complications comparable to TEE.
PMID:43034997 | DOI:10.1080/14779072.2026.2763891